設(shè)計(jì)依據(jù)1建筑設(shè)計(jì)規(guī)范:GB50011-2001《建筑抗震設(shè)計(jì)規(guī)范》
2交通標(biāo)準(zhǔn):JTGD62-2004《公路鋼筋混凝土及預(yù)應(yīng)力混凝土橋函設(shè)計(jì)規(guī)范》
3國家標(biāo)準(zhǔn):GB/T17900-2000《球型支座技術(shù)條件》
4建筑設(shè)計(jì)規(guī)范:GB50017-2003《鋼結(jié)構(gòu)設(shè)計(jì)規(guī)范》
設(shè)計(jì)參數(shù)分1支座豎向承載力分300KN,500KN,1000KN,2000KN,2500KN,3000KN,4000KN,5000KN,6000KN,7000KN,
8000KN,9000KN,10000KN十二個(gè)級(jí)別
2支座抗水平力為豎向承載力20%
3支座抗豎向拉力WJKQZ型,WJJQZ抗豎向拉力為豎向承載力的20%
WJGZ型,WJJGZ型抗豎向拉力為豎向承載力的30%
4設(shè)計(jì)轉(zhuǎn)角為0.08rad(可根據(jù)用戶要求另行設(shè)計(jì))
5支座的徑向位移±30-50mm,環(huán)向位移±60-100mm
6支座滑動(dòng)摩擦系數(shù)μ≤0.03(-25o--+60o)
7支座轉(zhuǎn)動(dòng)摩擦系數(shù)μ=0.05~0.1(WJKGZ型,WJJGZ型)
μ≤0.03(WJKZ,WJJGZ)